Products
- Radiology Equipments & Accessories[10]
- Remote Control[7]
- Ultrasonic[10]
- Clinical Analytical Instruments[10]
- Emergency & Clinics Apparatus[10]
- Other Electronic Components[4]
- Physical Therapy Equipments[4]
- Spectrometers[7]
- Laser Equipment[2]
- Other Lights & Lighting Products[1]
- General Assay & Diagnostic Apparatus[10]
- Dental Equipments[10]
- Surgical Instruments[10]
- Separation Equipment[8]
- Machinery Design Services[3]
- Hospital Beds[4]
- Sterilization Equipments[6]
- Drying Equipment[3]
- Water Filter[2]
- Medical Consumables[10]
- Ward Nursing Equipments[4]
- Bidets[1]
- Weighing Scales[1]
- Healthcare Supplement[1]
- Vacuum Cavitation System[2]
Contact Us
- Contact Person : Ms. Yi Nancy
- Company Name : Guangzhou Maya Equipment Co., Ltd.
- Tel : 0086-20-39160381
- Fax : 0086-20-39154381
- Address : Guangdong,Guangzhou,Room 409 ,Daxin business plaza, Shangjiao, Dashi town ,Panyu area, Guangzhou city China
- Country/Region : China
MA9000A patient monitor 15inches
Product Detailed
Related Categories:Physical Therapy Equipments
1,MA9000A patient monitor 15inches
2.Handheld and portable monitor
3,48 hours Memory storage
4,AC 180-220V power supply
ECG measurement: | |
Leads choices: | All, I, II, III, aVF, aVR, aVL V1--6 chest leads showed. |
Gains options: | × 1, × 2, × 4, and × 0.5 four trenches |
Frequency: | 0.5 Hz - 100 Hz |
Common-mode signal inhibition: | More than 70 dB |
Scan rate: | 12.5 mm/ S, 25 mm / S, 50 mm / S standard three stalls. |
HR: | ± 5 bpm |
Precision calibration signal: | 1mv(peak, ± 3% accuracy) |
ST Detection: | Measurement range(-1.0mV----+1.0mV) |
Using Standard: | meet the ANSI / AMI EC13 -1992 standard |
Response time: | 1s |
Alarm: | Sound and Light |
Preset heart rate range: | (Alarm over preset numerical) |
Ceiling: | 1-255 bpm adjustable |
Threshold: | 0-254 bpm adjustable |
RESP Breath | |
Breathing frequency range: | 0-60 bum |
Accuracy: | ± 1brpm |
Response time: | 1s |
Gains options: | × 1, × 2, × 4, and × 0.5 four trenches |
Alarm: | Sound and Light |
Alarm range: | (numerical preset alarm over) |
Ceiling: | 10-100 bpm adjustable |
Threshold: | 0 -99 bpm adjustable |
NIBP measurement | |
Technology: | Oscillometric |
Mode: | manual / automatic |
Measurement units: | mmHg / kpa |
Protection: | Double security protection |
A measurement time: | less than 45 S |
Scope: | Pressure Cuffs 0-250 mmHg |
Blood pressure measurement accuracy: | ANSI /AAMI, SP10-1992 standard error and standarddeviation of the average value of the initial |
Inflatable cuffs: | 180 mmHg (120 mmHg children newborn 70 mmHg) |
Inflatable cuffs follow: | original SBP: + 30 mmHg |
Blood pressure measuring range: | Systolic blood pressure: 60-250 mmHg |
Diastolic blood pressure: 40-220 mmHg | |
Pressure on the average: 45-235 mmHg | |
Response time: | 1s |
Alarm: | Sound and Light |
Preset range: | report (Numerical exceed preset alarm) |
Systolic blood pressure maximum: | 1-255 mmHg adjustable |
Threshold: | 0-254 mmHg adjustable |
Diastolic blood pressure ceiling: | 1 -255 mmHg adjustable |
Minimum standards: | 0 -254 mmHg adjustable |
Use standard: | compliance with the ANSI / AAMI SP10-1992 standard |
Spo2 measurement | |
Range: | 0-100% |
Accuracy: | 1% |
Resolution: | 1% |
Pulse frequency: | 20-250 times / min |
Response time: | 1s |
Alarm: | Sound and Light |
Preset range: | report (Alarm over preset numerical) |
Ceiling: | 1% - 100% adjustable |
Threshold: | 0% - 99% adjustable |
TEMP measurement: | |
Technology: | thermostat temperature probe |
Measuring range: | 20 ° C-45 ° C |
Temperature resolution: | 0.10% |
Accuracy: | ± 1 ° C |
Response Time: | 1s |
Alarm: | Sound and Light |
Preset range: | report (numerical preset alarm over) |
Maximum: | 20.1 ° C-45.5 ° C adjustable |
Threshold: | 20 ° C-45.4 ° C Adjustable |
Trend Graph: | |
Types: | Graphical /tabular |
Memory storage: | 48 hours (not restart preservation) |
Data interval: | 30 seconds |
Graphic form: | one graph per channel. |
Tabular form: | graphics are the parameters with 11 per trip (and time parameters). One page 15 firms external |
Power | |
AC power supply: | AC 180-220V, 50Hz-60Hz. 1A maximum current |
Temperature: | 0-40 ° C |
Storage temperature: | -20 °C-50°C |
Working humidity: g | 5-95% relative humidity, non-condensin |
Humidity storage: | 5-95% relative humidity, non-condensing |
Altitude: | 0-1000 feet (working condition) |
Whole Power: | not more than 40W |
MA9000A patient monitor 15inches