MA9000A Multi-function patient monitor

MA9000A Multi-function patient monitor
Product Detailed
Related Categories:Physical Therapy Equipments
MA9000A Multi-function patient monitor 1.Multi-function 2.Handheld and portable

Detail information

MA9000A Multi-function patient monitor 1.Multi-function 2.Handheld and portable

ECG measurement:

 
Leads choices: All, I, II, III, aVF, aVR, aVL V1--6 chest leads showed. 
Gains options:   × 1, × 2, × 4, and × 0.5 four trenches
Frequency:0.5 Hz - 100 Hz
Common-mode signal inhibition: More than 70 dB
Scan rate:12.5 mm/ S, 25 mm / S, 50 mm / S standard three stalls.
HR:± 5 bpm
Precision calibration signal:1mv(peak, ± 3% accuracy)
ST Detection:Measurement range(-1.0mV----+1.0mV)
Using Standard:meet the ANSI / AMI EC13 -1992 standard
Response time:1s
Alarm: Sound and Light
Preset heart rate range: (Alarm over preset numerical)
Ceiling:       1-255 bpm adjustable
Threshold:0-254 bpm adjustable
RESP Breath 
Breathing frequency range: 0-60 bum
Accuracy:   ± 1brpm
Response   time:  1s
Gains options: × 1, × 2, × 4, and × 0.5 four trenches
Alarm: Sound and Light
Alarm   range:    (numerical preset alarm over)
Ceiling:       10-100 bpm adjustable
Threshold:   0 -99 bpm adjustable
NIBP measurement 
Technology:  Oscillometric
Mode: manual / automatic
Measurement units: mmHg / kpa
Protection: Double security protection
A measurement time: less than 45 S
Scope: Pressure Cuffs 0-250 mmHg 
Blood pressure measurement accuracy:ANSI /AAMI, SP10-1992 standard error and standarddeviation of the average value of the initial
Inflatable cuffs: 180 mmHg (120 mmHg children   newborn 70 mmHg)
Inflatable cuffs follow: original SBP: + 30 mmHg
Blood pressure measuring range: Systolic blood pressure: 60-250 mmHg
Diastolic blood pressure: 40-220 mmHg
Pressure on the average: 45-235 mmHg
Response time: 1s
Alarm: Sound and Light
Preset range: report (Numerical exceed preset alarm)
Systolic blood pressure maximum: 1-255 mmHg adjustable
Threshold: 0-254 mmHg adjustable
Diastolic blood pressure ceiling: 1 -255 mmHg adjustable
Minimum standards: 0 -254 mmHg adjustable
Use standard: compliance with the ANSI / AAMI SP10-1992 standard
  
Spo2 measurement 
Range:0-100%
Accuracy: 1%
Resolution: 1%
Pulse frequency:20-250 times / min
Response time: 1s
Alarm: Sound and Light
Preset range:report (Alarm over preset numerical)
Ceiling:    1% - 100% adjustable
Threshold:  0% - 99% adjustable
TEMP measurement: 
Technology: thermostat temperature probe 
Measuring range: 20 ° C-45 ° C
Temperature resolution: 0.10%
Accuracy:± 1 ° C
Response Time: 1s
Alarm:Sound and Light
Preset range: report (numerical preset alarm over)
Maximum: 20.1 ° C-45.5 ° C adjustable
Threshold: 20 ° C-45.4 ° C Adjustable
Trend Graph: 
Types:Graphical /tabular
Memory storage: 48 hours (not restart preservation)
Data interval: 30 seconds
Graphic form:  one graph per channel.
Tabular form: graphics are the parameters with 11 per trip (and time parameters). One page 15 firms external
Power 
AC power supply: AC 180-220V, 50Hz-60Hz. 1A maximum current
Temperature: 0-40 ° C
Storage temperature: -20 °C-50°C
Working humidity: g 5-95% relative humidity, non-condensin
Humidity storage:5-95% relative humidity, non-condensing 
Altitude: 0-1000 feet (working condition)
Whole Power: not more than 40W