- Radiology Equipments & Accessories[10]
- Remote Control[7]
- Ultrasonic[10]
- Clinical Analytical Instruments[10]
- Emergency & Clinics Apparatus[10]
- Other Electronic Components[4]
- Physical Therapy Equipments[4]
- Spectrometers[7]
- Laser Equipment[2]
- Other Lights & Lighting Products[1]
- General Assay & Diagnostic Apparatus[10]
- Dental Equipments[10]
- Surgical Instruments[10]
- Separation Equipment[8]
- Machinery Design Services[3]
- Hospital Beds[4]
- Sterilization Equipments[6]
- Drying Equipment[3]
- Water Filter[2]
- Medical Consumables[10]
- Ward Nursing Equipments[4]
- Bidets[1]
- Weighing Scales[1]
- Healthcare Supplement[1]
- Vacuum Cavitation System[2]
- Contact Person : Ms. Yi Nancy
- Company Name : Guangzhou Maya Equipment Co., Ltd.
- Tel : 0086-20-39160381
- Fax : 0086-20-39154381
- Address : Guangdong,Guangzhou,Room 409 ,Daxin business plaza, Shangjiao, Dashi town ,Panyu area, Guangzhou city China
- Country/Region : China
CTN-TCI-VI double Channel Syringe Pump
Details information
Technology parameter
IV set requirement: 20ml,50/60ml Syringe rate range: 0.1~ 800ml/h (20ml) 0.1~1200ml/h (50/60ml) increase volume 0.1 ml/h Rapid Bolus rate: 800ml/h (20ml) 1200ml/h (50/60ml) Total volume: 0~999999 ml Syringe accuracy: ± 3 % (include machine accuracy ± 1 %) KVO 1ml/h occlusion pressure: 30-110Kpa, 3 mode adjustment Display screen: 240X128 pixel alarm: Automatic check,AC power source creepage,low battery,batter exhaust, occlusion in tube,drip finished,syringe finished,incorrect input,incorrect place Operation condition: Ambient temperature:+5°C~+40°C; relative humidity:20%~ 90%;Atmosphere pressure:70.0~ 106.0 kPa Power source AC supply:AC220V±22V,50Hz±1Hz; DC supply:DC14.4V,batter charge automatic when AC power source work. can used for 4 hours continuously when fully charged for 10 hours. Safe classification Class ii, type BF spray proof IPX1 Input power 25 VA Outer size: (L×W×H) 326 × 140× 265 (mm) weight 3.8kg
Technology parameter
IV set requirement: 20ml,50/60ml Syringe rate range: 0.1~ 800ml/h (20ml) 0.1~1200ml/h (50/60ml) increase volume 0.1 ml/h Rapid Bolus rate: 800ml/h (20ml) 1200ml/h (50/60ml) Total volume: 0~999999 ml Syringe accuracy: ± 3 % (include machine accuracy ± 1 %) KVO 1ml/h occlusion pressure: 30-110Kpa, 3 mode adjustment Display screen: 240X128 pixel alarm: Automatic check,AC power source creepage,low battery,batter exhaust, occlusion in tube,drip finished,syringe finished,incorrect input,incorrect place Operation condition: Ambient temperature:+5°C~+40°C: relative humidity:20%~ 90%;Atmosphere pressure:70.0~ 106.0 kPa Power source AC supply:AC220V±22V,50Hz±1Hz;DC supply:DC14.4V,batter charge automatic when AC power source work. can used for 4 hours continuously when fully charged for 10 hours. Safe classification Class ii, type BF spray proof IPX1 Input power 25 VA Outer size: (L×W×H) 326 × 140× 265 (mm) weight 3.8kg
CTN-TCI-VI double Channel Syringe Pump