Technical Data:

Specification of syringe 

SFDA registered disposable sterilized syringe       20ml ,50/60ml   (CTN-TCI-VI)          10ml,20ml,30ml,50/60ml   (CTN-TCI-V)

Speed range

0.1~ 800ml/h  (20ml)    0.1~1200ml/h (50/60ml)   increase volume 0.1 ml/h(CTN-TCI) 0.1~ 300ml/h  (10ml)    0.1~ 600ml/h (20ml)    increase volume0.1 ml/h(CTN-TCI-I)0.1~900ml/h(30ml)       0.1~1200ml/h (50/60ml) increase volume0.1 ml/h(CTN-TCI-I)

Bolus 

                800ml/h  (20ml)                  1200ml/h (50/60ml)  (CTN-TCI)   300ml/h(10ml)   600ml/h(20ml)   900ml/h(30ml)    1200ml/h (50/60ml)  (CTN-TCI-I)

Total volume 

0~999999 ml

Accuracy

± 3 % (including mechanic accuracy)

KVO rate 

1ml/h

Occlusion pressure limit 

30 to 110KPa,three gears(high/middle/low) for adjusting occlusion pressure

Display

240 X 128 pixel (CTN-TCI-VI)        240 X 160 pixel (CTN-TCI-V)

Alarm

Self detect, AC power creepage, battery under voltage,battery finish, blocking, medicine finish, infusion finish, data setting exceeds limit and improper placing.

Working condition 

Ambient temperature:+5°C~+40°C;  RH: ≤80%;atm press:86.0kPa~ 106.0kPa

Transporting and storing condition 

Temperature: -20°C~+55°C;       RH: ≤93%;  atm press:50.0kPa~ 106.0kPa

Power

a) AC power:AC220V±22V,50Hz±1Hz;  b) DC power:DC14.4V(1.2V × 12bite), Ni-mh rechargeable battery.When AC power is on, batteries will charge automatically. Batteries last 4 hours after charging for 10.

IP grade

Safty classification

IP×1 jawp-proof device 

ii series internal electric source BF type 

Input power 

25 VA    (CTN-TCI)        18 VA    (CTN-TCI-I)

Measurement

326 × 140× 265 (mm)   (CTN-TCI-VI)          300 × 130 × 145 (mm)  (CTN-TCI-V)

Weight

4 kg (CTN-TCI)         2.4 kg (CTN-TCI-I)