MA2000B3 Breathing Machine

MA2000B3 Breathing Machine
Product Detailed
MA2000B3 Breathing Machine 1. High-definition 10.4" TFT color LCD screen . 2. IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH (IMV,VC

Detailed Product Description

MA2000B3 Breathing Machine 1. High-definition 10.4" TFT color LCD screen . 2. IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH  (IMV,VCV)

MA2000B3 Breathing Machine

Ventilator:

1. Display mode                     High-definition 10.4” TFT color LCD screen display

2. Ventilation mode                IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH

(IMV, VCV, PCV)

3. Ventilation parameters       Tidal volume50~1500 ml (20~1500 ml)

Rate                1~99 bpm

SIMV rate        1~20 bpm

I:E                   2:1~1:8 (4:1~1:8)

Inspiratory trigger pressure      -1.0~2.0Kpa

PEEP                                          0~2.0Kpa

Pressure range                          1.0~6.0Kpa

SIGH                                           1.5 times the inspiratory time(70-150 adjustable)

Inspiratory platform                    0~50%

4. Parameters for ventilation monitoring     tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop)

5. Monitoring of oxygen concentration     21%~100%

6. Security Alarm System

Oxygen Concentration alarm       upper limit setting range 21%~100%

                                                    low limit setting range   10%~80%

Airway pressure alarm                 upper limit setting range  0.3~6.0 kPa

                                                    low limit setting range   0.2~5.0 kPa

Per-minute ventilation volume alarm       upper limit setting range  3.0~30L/min

                                                                low limit setting range   1.0~10L/min

Sustained high-pressure alarm      it will give alarm when stress have consistently

                                                       been higher than 2.5 kPa

Suffocation alarm                it will give sound and light alarm if there is

                                           no tidal volume input for 15 seconds

Power alarm

 

7. Power                          AC 220V±10%     50Hz±1Hz

                                        UPS, Storage battery

8. Mechanical Arms

9. (Air compressor) 

MA2000B3 Breathing Machine



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.