MA125 125mA Medical x-ray machine

MA125 125mA Medical x-ray machine
Product Detailed
Related Categories:Vacuum Cavitation System
MA125A 125mA Medical x-ray machine Single table and single tube

MA125A  125mA Medical x-ray machine

USE

General radiography, Filter-ray-filter radiograph

Unit Configuration  

Control,HT generator unit,Ht cable,X-ray tube unit,Radiographic table-X-ray source column,Collimator 

Function

The unit can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones in lying

Feature

1,  meter-indicating

2,  single-table single tube

3,  single-phase, full wave rectification

4,  stationary anode x-ray tube assembly

5,  X-ray tube filament s voltage regulator, space charge compensator

6,  Radiograph plain table wimple structure and easy assembling

MIN TECHNICAL INDEXES

ITEM

CONTENTS

INDEX

Demand of power supply

Capacity

Two-phase 30KVA

Voltage,Frequency

380V/220V   ±10%50HZ ±0.5Hz

Intemal resistance

2Ω(380V)  0.6  Ω(220V)

power supply

Adjustable range

380±10% at220V being adjustable continuously

Radiograph

Voltage

50-90KV

current

Small focus: 15mA,Big focus:30mA 60mA 100mA 125mA

time

0.04~6.35s 23grades together grading a according to R10 coefficient

High-voltage generator

Capacity

7KVA

Max DC output voltage

90KV

Max DC output current

125mA

X-Ray tube

Model

XD4-2.9/100

Focus

Small focus 1.8×1.8mm  big focus4.3×4.3mm

Radiographic

table

Length×width×height of bed surface

2000mm×665mm×700mm

Moving range of bed surface

640mm in Length

Ray-filter of table

Travel in length ≥50mm

Grid density N=28

Convergence distance f.=100cm

r=8/Grid ratio r=8

Column of X-ray tube unit

Moving Longitudinally along Radiographic table

1000mm or 1800mm

Distance to friend as moving up and down (along column)

650~1800mm

Rotary around the center of cross arm

±180°

Rotary around the shaft line of X-ray annular tubes 

-10°~60°~  +120°

Max size of cassette

356mm×432mm(14″×17″)

Note: We will not make another notice if the contour of product and technical parameters will be changed